Home / Products / Load Break Tools / Rugged 34.5KV LoadBuster for Transformers

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Rugged 34.5KV LoadBuster for Transformers

Available in two system-matched models
  • 14.4/25 kV nominal, 27 kV maximum
  • 25/34.5 kV nominal, 38 kV maximum
  • Interrupts with no external arc. Meets OSHA requirements for opening circuits under load
  • Handles all live-switching duties — transformers, lines, cables, and capacitors . . . through 38 kV, 900 A
  • Rugged, reliable. Loadbuster’s robust, low-maintenance design stands up to the most demanding use . . . up to 2000 operations between inspections
  • Operation counter feature tracks tool use, helps determine maintenance needs
  • Cuts installation and operation costs. No need for interrupters on each device . . . simplified switching procedures minimize duration and scope of outages
  • Total factory support. Loadbuster and replacement parts available for immediate delivery.
Availability:
Quantity:
  • SL-35

  • SASUN

  • 8535309090-3

Product Overview

The Loadbuster tool is the original lightweight, easy-to-use portable load break tool for use with disconnects, cutouts, power fuses, and fuse limiters. It brings load-switching capability through 34.5 kV and 600 amperes nominal, 900 amperes maximum to your overhead distribution system. The Loadbuster tool cuts installation and operation costs. There’s no need for load interrupters on each device. Switching procedures are simplified too . . . minimizing the duration and scope of outages. This rugged, reliable device interrupts with no external arc, meeting OSHA requirements for opening circuits under load.


Product Advantages

Superior Arc Interruption Performance

This LoadBuster is engineered to handle high-voltage load breaking with precision. Its internal arc-extinguishing mechanism ensures that electrical arcs are safely contained and quenched, eliminating the risks associated with uncontrolled arc exposure. This translates into safer operations and greater confidence during every switching task.

Designed for 34.5kV Systems

Tailored specifically for higher voltage applications, this tool meets the demands of modern distribution networks. It provides reliable performance in transformer switching, ensuring compatibility with medium-voltage systems and reducing operational limitations.

Rugged and Field-Ready Construction

The tool’s robust build is designed to withstand harsh outdoor conditions, including temperature fluctuations, moisture, and mechanical stress. Its durable structure ensures long-term reliability, even with frequent use in demanding utility environments.

Improved Operational Efficiency

By enabling load breaking without system shutdown, the LoadBuster reduces downtime and enhances service continuity. This efficiency is crucial for utilities aiming to maintain uninterrupted power supply while performing maintenance.


SL-35-001 SL-35-002 SL-35-003
SL-35-004 SL-35-006 SL-35-007


Product Features

Advanced Arc-Quenching Chamber

At the heart of the tool lies a precision-engineered arc chamber that captures and extinguishes the arc during load interruption. This ensures a controlled and predictable operation, protecting both the operator and surrounding equipment.

Optimized for Hot Stick Operation

The tool is fully compatible with standard insulated hot sticks, allowing operators to maintain a safe working distance. Its connection interface is designed for secure engagement, ensuring stability during operation.

High Durability Insulation System

The insulating components are designed to resist environmental stress and electrical wear, ensuring consistent performance over time. This reliability is essential for tools used in high-voltage applications.


Application Scenarios

Transformer Switching Operations

In transformer maintenance and replacement, this LoadBuster allows safe disconnection under load conditions, minimizing service interruptions and ensuring operational continuity.

Medium-Voltage Distribution Networks

For utilities managing 34.5kV systems, the tool provides a dependable solution for load breaking, supporting efficient and safe network management.

Emergency Power Restoration

During fault conditions or urgent repairs, the tool enables quick and safe isolation of components, helping restore power faster and reducing downtime.


FAQ

Q1: Is it suitable for live-line operations?

Yes, it is designed for use with insulated hot sticks in energized environments.

Q2: What type of maintenance is required?
Routine inspection and cleaning are sufficient to maintain optimal performance.

Q3: Does it require special training?
Operators should have basic training in live-line work to ensure safe and effective use.


Previous: 
Next: 
Sasun International Electric Co., Ltd, was established in 2001, As a professional manufacturer & exporter on high voltage overhead line product in China

QUICK LINKS

PRODUCTS

CONTACT US

Inquire
Copyright © 2024 Sasun International Electric Co., Ltd. All Rights Reserved.  Sitemap