| Availability: | |
|---|---|
| Quantity: | |
sasun
Core Benefits:
✅ Quick installation
No heat source or tools are required, and the pull-out design can be installed in 15 minutes by one person, avoiding the risk of overheating in the shrink process.
Adaptive cable outer diameter tolerance (±10%), elastomer tight fit, no hidden danger of uneven shrinkage.
✅ Triple protection
Electrical protection: integrated stress cone + high dielectric constant material, uniform electric field distribution (partial discharge ≤5pC).
Environmental protection: UV resistance, ozone resistance, acid and alkali salt spray resistance, applicable temperature range -50°C~+90°C.
Mechanical protection: tear-resistant outer sheath, protection class IP68, no additional protective box is required for direct burial or cable well installation.
✅ Adaptable
Conductor cross-sections cover 25-630 mm² (single core) and 3×35-3×400 mm² (three cores).
Armoured/unarmoured cables are supported, with the option of pluggable (T-type) or fixed termination construction.
| parameter | 12/20(24)kV | parameter ... |
| Rated voltage | 12/20(24)kV | IEC 60502-4 |
| Bauerfrey, Tseng, Westhold, Voltagui | 50kV/5min(DRY) | GB/T 3048.8 |
| Westander Lightning, Inpsvoltagee | 125kV | GB/T 3048.13 |
| Partial discharge | ≤5pC(1.5U₀电压下) | IEC 60270 |
| Minimum bend radius | 12×Cable outer diameter | - |
| Applicable conductors | Cu/Al(Copper-aluminum transition requires special terminals) | - |
| Tightness | 0.3MPaNo leakage at water pressure/48h | GB/T 2423.38 |
| Life cycle | ≥30年 | - |
Core Benefits:
✅ Quick installation
No heat source or tools are required, and the pull-out design can be installed in 15 minutes by one person, avoiding the risk of overheating in the shrink process.
Adaptive cable outer diameter tolerance (±10%), elastomer tight fit, no hidden danger of uneven shrinkage.
✅ Triple protection
Electrical protection: integrated stress cone + high dielectric constant material, uniform electric field distribution (partial discharge ≤5pC).
Environmental protection: UV resistance, ozone resistance, acid and alkali salt spray resistance, applicable temperature range -50°C~+90°C.
Mechanical protection: tear-resistant outer sheath, protection class IP68, no additional protective box is required for direct burial or cable well installation.
✅ Adaptable
Conductor cross-sections cover 25-630 mm² (single core) and 3×35-3×400 mm² (three cores).
Armoured/unarmoured cables are supported, with the option of pluggable (T-type) or fixed termination construction.
| parameter | 12/20(24)kV | parameter ... |
| Rated voltage | 12/20(24)kV | IEC 60502-4 |
| Bauerfrey, Tseng, Westhold, Voltagui | 50kV/5min(DRY) | GB/T 3048.8 |
| Westander Lightning, Inpsvoltagee | 125kV | GB/T 3048.13 |
| Partial discharge | ≤5pC(1.5U₀电压下) | IEC 60270 |
| Minimum bend radius | 12×Cable outer diameter | - |
| Applicable conductors | Cu/Al(Copper-aluminum transition requires special terminals) | - |
| Tightness | 0.3MPaNo leakage at water pressure/48h | GB/T 2423.38 |
| Life cycle | ≥30年 | - |